FTIR Gas Analyzer

Vasthi Instruments are global leaders in manufacturing of FTIR Gas Analyzer and have been supplying instruments to customers worldwide, Our multidisciplinary team of scientists, physicians, engineers, and regulatory consultants with decades of global experience brings you the quintessential mechanism that provides complete safety accuracy and durability.

Vasthi Instruments was formed with visionary thinking and innovative ideas resulting in innovative products and solutions. We enhance our product quality by the continuous process of research and development. We have WIDE range of models to suite various site conditions and processes.
FTIR ANALYZER

CATALOG

FTIR Gas Analyzer 8000 is one of the most powerful gas analyzers you can buy. FTIR Gas Analyzer 8000 (VE FT-8000 IR system) is a gas on-line continuous monitoring system based on Fourier transform infrared spectroscopy. monitoring emission gas of so2, Nox (NO,NO2)ch4,nh3,hcl,hf,co.co2,c2,o2,h2o and other components at the same time ,and can extend other components such as So2,N20, etc.

According to user demand FTIR Gas Analyzer 8000 (VE FT-8000 IR system) has high measurement precision, wide dynamic range. Low detection limit is suitable for ultra-low emission monitoring.FT-3000 uses the hot wet sampling technology with the entire heat tracing above 180c, avoids corrosion to the system in the process of condensation sampling effectively. Operates continuously and stably, especially is suitable for on-line monitoring in harsh field of high dust, high dist humidity, high corrosion (e.g..incinerator)

Applications:

  • Waste incineration power plant
  • Ultra-low emission monitoring
  • Solid waste treatment plant
  • Marine exhaust emission

FEATURES

  • Measuring so2,Nox(No, No2),CH4,NH3,HCL,H F,C0,C02,02,H20, and other Components at the same time and can extend other components such as so2, n2o, etc.
  • The sampling probe adopts unique filtering method. good filtering effect, high blow efficienc6.long probe maintenance period.
  • The entire heating above 180c to prevent components loss of gas pollutant compositions from condensation.
  • A white cavity design  ,high signal-to-noise ratio,  measuring optical path up to 13m,Iow detection limit   ,wide dynamic range,  meet the requirements of ultra-low emission monitoring  .
  • Using the least squares method and the PLS algorithm, selecting the appropriate wavelength range. can effectively eliminate the interference of H2O and other components.
  • Interior cavity mirror of gas cell is plated with gold, high reflectivity. Constant temperature to above 180c is applicable to industrial field. Protect gas purging. Long gas cell maintenance period.

TECHNICAL SPECIFICATIONS

Gas So2 NO NO2 NOX CH4 NH3 HCL HF CO CO2 H20 O2
Range (0-75)Mg/m2 (0-200)mg/m2 (0-40)mg/m2 (0-200)mg/m2 (0-20)mg/m2 (0-10)mg/m2 (0-15)mg/m2 (0-10)mg/m2 (0-75)mg/m2 (0-20)% (0-40)% (0-25)%
Detection Limit 0.45mg/m2 0.90mg/m2 0.38mg/m2 0-15mg/m2 0-10mg/m2 0.35m

g/m2

0.25mg/m2 0.20mg/m2 0.03% 0.10%
Zero drift <+2%F.S./7d
Span drift <+2%F.S./7d
Linearity error <+2%F.S