Online TSS Water Analyzer that provides digital sensor technology and covers Dissolved Oxygen, Total Suspended Solid(TSS), Liquid Density and Conductivity measurements. Online TSS Water Analyzer adopts the pulse xenon lamp as light source and the ultraviolet optical fiber spectrometer as detector is capable for real-time gathering of absorption spectrum of water pollutants ranging from 200nm to 800nm and real-time analysis of the content of water pollutants by means of chemometric algorithm technology. Online TSS Water Analyzer includes two parts: the control box and the probe. The control box is installed in the analysis cabin and the probe is submerged in the water and fixed by means of mounting bracket the two parts are connected via cable. The control box provides power supply to the probe and at the same time receives the measurement value from the probe and displays them on the interface.
Online TSS Water Analyzer
Vasthi Instruments are global leaders in manufacturing of Online TSS Water Analyzer and have been supplying instruments to customers worldwide, Our multidisciplinary team of scientists, physicians, engineers, and regulatory consultants with decades of global experience brings you the quintessential mechanism that provides complete safety accuracy and durability.
Vasthi Instruments was formed with visionary thinking and innovative ideas resulting in innovative products and solutions. We enhance our product quality by the continuous process of research and development. We have WIDE range of models to suite various site conditions and processes.
Features
- It requires no reagents, so it can save operating costs and will cause no secondary pollution
- The response is quick (about 2 seconds). It is suitable for the occasion where high real-time performance is required, such as industrial process analysis
- Free from the interference of chloride ion
- It adopts full-spectrum measurement and chemometric algorithm analysis, which in comparison with the simple dual wavelength background subtraction technology, can measure more parameters and is less likely to be influenced by the compositional change of waste water
- All components are independently researched and developed
- It adopts pulse blowing method to clean the pollutants on the two window surfaces.
The instrument probe in the water measures organics in the water by means of xenon lamp. The calculation of spectrum obtained after each measurement will produce a measured value, which will be transmitted to the control box and displayed
- Optical fiber on the main interface. One measurement only takes several dozens of seconds. Meanwhile, in the interval of measurement, the instrument will be automatically cleaned to prevent contaminants from being deposited on the surface of the lens
- Model: V.WATER – 8001
TECHNICAL SPECIFICATIONS
Measuring Parameters |
COD, BOD, UV254, Nirate, TOC, DOC, Turbidity, TSS, Color, etc. |
Measuring Range |
As Customer required |
Method |
UV/visible differential optical absorption spectroscopy, wavelength range 200-800nm |
Power |
230V AC, 30w |
Linearity |
2% F.S. |
Zero drift |
<1% F.S. |
Range (COD) |
0-50-200mg/l, greater range can be customized |
Interval |
The shortest 60 seconds, the cycle can be set |
Probes Depth |
<10m |
Optical Path |
Can be adjusted according to the site condition |
Working Temperature |
5°C – 45°C |
Enclosure Rating |
IP65 (secondary instrument) |
Auto-cleaning |
Auto-cleaning |
Interface |
RS232/RS485 (Baud rate can be set), 2×4 -20ma output |
Probe Size |
60*380.55mm |
Probe Weight |
5kg |
Interface digital |
Ethernet (TCP/IP), RS-232 or RS-485 (Modbus RTU) |
Power Supply |
12-24 VDC (±10%) |
Output data |
|
Power consumption |
Power consumption |
Environmental conditions |
|
Sample temperature |
+2…+40 °C |
Ambient temperature |
+2…+40 °C |
Inflow velocity |
0.1-10m/s |
Performance Characteristics |
|
Maintenance effort |
Typically < 0.5 h/month |
Calibration/ maintenance interval |
24 months |
System compatibility |
Modbus RTU |
Guarantee |
1 year (EU:2year) |
Installation |
|
Max. pressure with sub Conn |
30 bar |
Max. Pressure with fixed cable |
3 bar |
Max .pressure in flow cell |
1 bar,2-4 L/min |
Protection type |
IP 68 |
Structural design |
|
Housing material |
Stainless steel (1.4571/1.4404)or titanium(3.7035) |
Weight Stainless steel |
~3kg (with 10mm path) |
Weight titanium |
~3kg (with 10mm path) |